Respuestas rápidas
- ¿Para qué se usa Anticoagulant citrate phosphate dextrose adenine?
- La etiqueta aprobada por la FDA (Teruflex Blood Bag System with Diversion Blood Sampling Arm 70 Ml CPDA-1, Terumo Corporation, 10 de octubre de 2024) dice, en inglés: “1. INDICATIONS AND USAGE 1.1. Read these instructions carefully before use. 1.2. Rx ONLY. 1.3. Intended for the collection, processing and preservation of Whole Blood and blood components. Not intended for direct intravenous infusion. 1.4. For the collection of 450 mL ±10% or 500 mL ±10% Whole Blood. 1.5. …” Esta página no es un consejo médico. Hable con su médico o farmacéutico antes de empezar, dejar o cambiar cualquier medicamento.
- ¿Anticoagulant citrate phosphate dextrose adenine tiene una advertencia en recuadro?
- No. Ninguna de las 14 etiquetas de la FDA que encontramos para este medicamento tiene advertencia en recuadro.
- ¿Hay escasez de Anticoagulant citrate phosphate dextrose adenine?
- La FDA no indica una escasez actual para los productos de este medicamento (datos de la FDA del 13 de noviembre de 2026).
- ¿Se ha retirado del mercado Anticoagulant citrate phosphate dextrose adenine?
- No aparece ningún retiro vinculado a los productos de este medicamento en los informes de la FDA que usamos.
- ¿Quién fabrica Anticoagulant citrate phosphate dextrose adenine?
- 2 empresas tienen productos con receta de Anticoagulant citrate phosphate dextrose adenine en el directorio NDC de la FDA, entre ellas Fenwal, Inc. y Terumo Corporation.
Para qué se usa Anticoagulant citrate phosphate dextrose adenine
Cita de la sección «Indications and Usage» (indicaciones y uso) de la etiqueta aprobada por la FDA. Se muestra en inglés, tal como la publica la FDA.
1. INDICATIONS AND USAGE 1.1. Read these instructions carefully before use. 1.2. Rx ONLY. 1.3. Intended for the collection, processing and preservation of Whole Blood and blood components. Not intended for direct intravenous infusion. 1.4. For the collection of 450 mL ±10% or 500 mL ±10% Whole Blood. 1.5. …
— Etiqueta de la FDA: Teruflex Blood Bag System with Diversion Blood Sampling Arm 70 Ml CPDA-1, Terumo Corporation, vigente desde el 10 de octubre de 2024. Leer la etiqueta completa en DailyMed →
Etiqueta citada: la de la presentación más común (solution, intravenous), Teruflex Blood Bag System with Diversion Blood Sampling Arm 70 Ml CPDA-1, Terumo Corporation; abarca 1 producto del directorio NDC de la FDA. Las citas sobre efectos secundarios, interacciones, dosis y embarazo de abajo vienen de esta misma etiqueta.
La FDA tiene 14 etiquetas para productos de este medicamento (distintos fabricantes y presentaciones); los usos pueden variar. Revise la etiqueta de su propio medicamento.
Esta página no es un consejo médico. Hable con su médico o farmacéutico antes de empezar, dejar o cambiar cualquier medicamento.
Advertencia en recuadro
La advertencia en recuadro («caja negra») es la advertencia más seria de la FDA en la etiqueta de un medicamento, para riesgos graves o mortales.
La etiqueta citada arriba no tiene advertencia en recuadro.
0 de 14 etiquetas de la FDA de este medicamento tienen advertencia en recuadro.
Dosis de Anticoagulant citrate phosphate dextrose adenine
Cita de la sección «Dosage and Administration» (dosis y administración) de la etiqueta aprobada por la FDA. Se muestra en inglés. Su dosis es la que le receta su médico: no la cambie por su cuenta.
2. DOSAGE AND ADMINISTRATION 2.1. To open blister package, peel cover film back 4/5 of its length. 2.2. Prepare the blood bag following your institution's standard operating procedures. 2.2.1. Materials Needed: VENOJECT II Tube Holder (code P-1316R) or equivalent VENOJECT II Multi-Sample Luer Adapter (code MN*2000T) or equivalent Evacuated blood collection tubes (glass or plastic) 2.3.
Leer más de esta sección
Make a loose knot in the donor tubing below the "Y" and CLIKTIP (inline closure device) unless alternate methods are used to seal the tubing at the end of collection. 2.4. Temporarily clamp donor tubing between the phlebotomy needle and the "Y". 2.5. Close the White Clamp below the diversion pouch. 2.6. Assemble the luer adapter and the tube holder. 2.6.1. Connect the VENOJECT II Multi-Sample Luer Adapter to the VENOJECT II Tube Holder (or equivalent) (Fig. 1). 2.6.2. Twist and snap to remove the blue port cap at the end of the Diversion Blood Sampling Arm (Fig. 2a). 2.6.3. Insert the Holder/Luer assembly in the female luer port (Fig. 2b). 2.6.4. NOTE: Alternatively, steps 2.6.1., 2.6.2., and 2.6.3. (above) may be performed at any time during bag preparation or after the blood is collected into the diversion pouch. 2.7. Suspend the collection bag as far as possible below the donor's arm. 2.8. Apply blood pressure cuff or tourniquet to donor's arm. Disinfect site of phlebotomy according to institutional standard operating procedures. If blood pressure cuff is used, inflate to approximately 60 mmHg. 2.9. Remove the needle cover and perform phlebotomy. Remove the temporary clamp on the donor tubing to permit blood flow into the Diversion Blood Sampling Arm pouch. 2.9.1. CAUTION: Do not touch the needle after removing the needle cover. 2.9.2. CAUTION: Assure that the White Clamp below the pouch is closed prior to initiating phlebotomy. 2.10. Secure the needle safety device in place following the device instructions provided on the reverse side. 2.11. Secure donor tubing to donor's arm. 2.12. Position the diversion pouch with the notches up and the Tube Holder/Luer Adapter assembly (or port cap) down. When the level of blood in the pouch is approximately in line with the notches, the diversion pouch is full (Fig. 3a). 2.12.1. NOTE: The approximate fill volume of the pouch at the notches is 35 mL. 2.13. Permanently seal the tubing between the "Y" and the diversion pouch to maintain a closed system using an aluminum clip or a tube sealer approved for use with tubing connected to a donor (Fig. 3b). 2.13.1. CAUTION: Do not use a dielectric tube sealer to seal the tubing while the needle is connected to the donor's body unless it is approved for such a purpose. 2.14. To initiate blood flow into the collection bag, break the CLIKTIP between the "Y" and the collection bag. 2.15. To avoid clot formation, collect samples as soon as possible from the diversion pouch as follows (Fig. 3b). 2.15.1. CAUTION: Do not collect donor test samples until the tubing between the "Y" and the diversion pouch is permanently sealed. 2.15.2. Open the White Clamp on the tubing below the pouch to open the pathway for sampling. 2.15.3.
— Etiqueta de la FDA: Teruflex Blood Bag System with Diversion Blood Sampling Arm 70 Ml CPDA-1, Terumo Corporation, vigente desde el 10 de octubre de 2024. Esto es solo una parte de la sección. Leer la etiqueta completa en DailyMed →
Presentaciones y vía de administración
| Formas farmacéuticas | Solución |
|---|---|
| Vía | Intravenosa |
| Productos con receta | 14 en el directorio NDC de la FDA |
| Nombres de marca | CPDA-1, Teruflex Blood with Diversion Blood Sampling Arm 70 Ml CPDA-1, Teruflex Blood Bag System with Diversion Blood Sampling Arm 70 Ml CPDA-1, Teruflex Blood Anticoagulant Citrate Phosphate Dextrose Adenine (Cpda-1) for Collection of 450ml of Blood |
Empresas que tienen este medicamento
Empresas en el directorio NDC de la FDA: la empresa que aparece en el envase (fabricante o distribuidor), con su número de productos con receta.
- Fenwal, Inc.11 productos
- Terumo Corporation3 productos
Historial de aprobación de la FDA
No hay ninguna solicitud de Drugs@FDA vinculada a estos productos.
Escasez
La lista de escasez de la FDA no incluye estos productos.
Retiros del mercado
No aparece ningún retiro vinculado a estos productos (por su código NDC) en los informes de la FDA.
Identificadores oficiales
| ID (SPL set ID) de la etiqueta citada | 86b3a329-c83f-4977-92f5-0e9dfe1872d7 |
|---|---|
| Etiquetas de la FDA (SPL) | 14 |
| Principios activos (FDA) | ADENINE / ANHYDROUS CITRIC ACID / DEXTROSE MONOHYDRATE / SODIUM PHOSPHATE, MONOBASIC, MONOHYDRATE / TRISODIUM CITRATE DIHYDRATE |
Siguientes pasos
- Encuentre una farmacia cerca de ustedPregunte qué precio le corresponde y si su producto está afectado por un retiro
- Últimos retiros de medicamentos de la FDATodos los medicamentos, los más recientes primero
- CPDA-1Página de marca: productos, fabricante y precio
- Fenwal, Inc.Fabricante o distribuidor
- Terumo CorporationFabricante o distribuidor
- Todos los medicamentos con receta de la A a la ZBusque por nombre genérico, de marca o en español
Fuentes
- Etiqueta aprobada por la FDA en DailyMed (Biblioteca Nacional de Medicina) — Teruflex Blood Bag System with Diversion Blood Sampling Arm 70 Ml CPDA-1, Terumo Corporation, vigente desde el 10 de octubre de 2024; vía openFDA, datos de la FDA exportados el 13 de noviembre de 2026, consultados el 14 de noviembre de 2026
- NDC Directory (openFDA) — Administración de Alimentos y Medicamentos de los EE. UU. (FDA), datos de la FDA exportados el 13 de noviembre de 2026, consultados el 14 de noviembre de 2026
- Drugs@FDA (openFDA) — Administración de Alimentos y Medicamentos de los EE. UU. (FDA), datos de la FDA exportados el 13 de noviembre de 2026, consultados el 14 de noviembre de 2026
- Drug recall enforcement reports (openFDA) — Administración de Alimentos y Medicamentos de los EE. UU. (FDA), datos de la FDA exportados el 10 de noviembre de 2026, consultados el 14 de noviembre de 2026
- Drug shortages (openFDA) — Administración de Alimentos y Medicamentos de los EE. UU. (FDA), datos de la FDA exportados el 13 de noviembre de 2026, consultados el 14 de noviembre de 2026
La FDA ofrece los datos de openFDA tal cual; pueden estar incompletos. Guíese siempre por la etiqueta que viene con su medicamento. Buscador de informes de retiros de la FDA →
Informar un error → · Información para fabricantes de medicamentos